Manual screw slides




















Applications Include:. How to Order. X-Y Slide Tables. Each lead screw and carriage operates independently. Right Angle Gearbox — Allows the control knob or wheel to be offset perpendicular to the UniSlide ways. Ideal for tight spaces or applications where access to the end of the stage is limited. For more specifics and to see the gearbox in use on a Velmex stage visit the UniSlide Adapters page.

Way Covers -WC — Protect the slider and dovetail base from dust, dirt and grit that could hamper the efficient operation of the slide. Way covers increase slider height and reduce the travel length of linear UniSlide stages. Not available on Series A15 Assemblies. Available on free sliding, screw drive and graduated knob models of the other assemblies. For more details visit the Way Cover page. Wrench - Retainer Nut — Velmex has a custom-designed wrench to easily adjust and remove the threaded retainer nut on UniSlides.

When needed, this makes removing and changing the lead screw simple and easy. Finishes — Standard UniSlide Assemblies have a brushed aluminum finish. Optional finishes are available at an additional charge and include:.

An encoder, mounted directly to the slider gives a true and accurate reading eliminating lead screw and backlash errors. It can monitor one or two axis. Fully functional, it features automatic memory back-up of settings, sleep mode and self diagnostics. It's highly visible, wide-screen LED display makes it easy to view the positioning results. Not available on all UniSlide models. Velmex offers a multitude of options and accessories for all its products. Usually an option or an accessory will address your requirements.

When it doesn't, we can make custom modifications, including:. You will also see. STP files, you may need to right click on the download button and save the "target" or "link". If you require a different format or cannot located the drawing you require, please contact us. Drawings are identified by the series and configuration.

The complete part number can be found on the side or end of any Velmex device you may already own. For example - APS2. For non-standard sizes or multi-axis configurations, please contact us. There may be an additional charge. These are examples of Velmex products. If you wish a similar product, please contact us with your specific application specifications travel distance, payload, hours per day in use, resolution, speed range, etc.

You can use the Request Assistance form. The example displayed may be a custom configuration, designed to the customer's specifications; and not offered as a standard product. Custom configurations could contain custom, externally-fabricated components. Pictured in our gallery are examples of configurations and systems using manual UniSlide Assemblies, along with configurations that also include other Velmex products. Product and accessory offering is subject to change and availability. Velmex also offers motorized UniSlide Assemblies.

Examples of other Velmex products can be found on the Examples page or in the Examples section for each product. Additional FAQs about product comparisons, product construction, purchasing and shipping can be found on the company FAQ page. First - always read the Users Manual. Lubrication is important for motor-driven systems or wherever you want maximum life and the lowest friction.

Only a few drops are required to keep your slide running smoothly. The load and hours of use effect the amount and frequency of lubrication. See the user guide that came with your UniSlide for recommendations. Mounting UniSlide assemblies in multi-axis systems requires the use of adapter plates and brackets.

They also can be combined with Velmex Rotary Tables and our other linear stages to make custom systems to meet a wide range of applications. See UniSlide Options and Accessories for more information on the plates and adapters.

UniSlides have pre-drilled holes in the base. The surface should be flat to avoid binding and for the slide to operate smoothly and accurately. Steel or aluminum are recommended for the surface. Use the mounting screws provided. Begin in the center of the base and work toward the ends uniformly tightening the screws. Refer to the UniSlide Users Manual for the torque specifications.

You need to disassemble an A15 Series UniSlide in order to mount it on to a surface or another slide. Please follow our Disassemble A15 Series Instructions. An adjustable expansion gib controls the fit of the UniSlide carriage. Adjust by tightening the Allen head screws located at the end of the slider. See the UniSlide Owners Manual for how and when to adjust. UniSlide Stages cannot be converted, except at the factory. You should purchase the version you require at the onset.

It is possible, however, to buy Velmex UniSlide Stages pre-configured for both manual and motorized operation with a double shaft stepper motor. Options and accessories like revolution counters can be added to Velmex assemblies after the fact.

However, because of special adjustments, possible cutting or turning and additional hardware that may be required, the assembly needs to be returned to the factory to properly fit the additional component. There is a nominal charge for reconfiguring assemblies. If you have questions about your specific application or want us to design a UniSlide System for you, please complete the Request Assistance form or call Velmex to speak to one of our Application Engineers. Rotary Tables Turntables.

Pre-Configured Systems. Controllers Motors Encoders Readouts. Velmex, Inc. Linear Series Part number information for each style can be found under Specifications at the end of the page. UnSlide Style Configurations. Inches cm Inches cm A15 15 6. A15 15 6. Repeatability 0. Consult factory. Load Parameters Definitions and parameters that effect the various load ratings.

Lead Screws A wide selection of high-quality lead screws provide flexibility in designing the drive portion of Velmex translation stages. Click to open the section you need: "Right Click" to download. Example: ASU1. Exp: ASU Combination Assemblies Click to Open.

Emp: ACUB Working Images Click to Open. Adjusting sliders. During mounting, the base may have been over-tightened or mounted to an irregular surface. This can distort the assembly, causing carriage binding. Loosen screws and re-tighten to the proper torque.

Mounting non-flat plate or blocks to the carriage to hold the load can also distort the assembly, causing carriage binding. Anything attached to the assembly must be mounted flat to the carriage. A linear scale and micrometer-like hand wheel measure travel distance in increments of 0.

Rulon sleeve bearings allow these slides to move smoothly, even in dirty environments. Use them in a variety of manual-positioning applications for laboratory and production equipment as well as for positioning parts for drilling, fastening, assembly, and measuring. Made with Frelon bearings, these slides have over four times the load capacity of standard positioning slides.

They have a precision lead screw for use in a variety of manual-positioning applications for laboratory and production equipment as well as for positioning parts for drililng, fastening, assembly, and measuring.

Two- axis mounting plates sold separately let you mount two slides together for motion along two axes. Connect to an electric motor with the included NEMA mounting flange. Slides have a precision lead screw, ball bearing carriage, and shaft coupling already installed. Travel distance per turn, also known as screw lead, is the distance a load moves with one revolution of the lead screw. The micrometer handles ensure accurate, repeatable positioning along a single axis— good for positioning parts, such as measuring and inspecting equipment, that are part of a larger automated system.

A knurled knob locks the slide without affecting its position. The micrometer handles ensure accurate, repeatable positioning along two axes— good for positioning parts, such as measuring and inspecting equipment, that are part of a larger automated system.

The micrometer handles ensure accurate, repeatable positioning along three axes— good for positioning parts, such as measuring and inspecting equipment, that are part of a larger automated system.

The slides become an extension of the arm, so you can program how they glide back and forth on the rail as part of the robot's work cycle.

A cable management system keeps your cables from tangling while the slides are in motion. System of Measurement. Travel Length. Overall Length. Overall Width. Static Load Capacity. Number of Mounting Holes. Handle Type. Bearing Material. Mounting Hole Location. Carriage Length. Carriage Width. Lead Screw Material.



0コメント

  • 1000 / 1000